To configure an Allied Telesyn router to send messages to a syslog daemon, you'll have to create a log output definition, which will send the messages to a syslog daemon. Use the following command to create the output definition:

create log output=1 destination=syslog secure=yes server=address

Where address is the IP address of the host running the syslog daemon. Having created this output definition, you must add filters to the definition to tell it what sort of log messages to send.
For example, if you want to send messages that are generated by the IP traffic filters, the command would be:

add log output=1 type=IPFILT

Or, if you want to log the durations of all ISDN calls, the command would be:

add log output=1 mod=ICC type=CALL subtype=DOWN


Still problems enabling syslog? Find the solution in our forum or post a question there!

Syslog messages generated by these products can be received by MonitorWare Agent and WinSyslog.

All information in this section is to the best of our knowledge but without warrenty of any kind. This is free information - use it at your sole risk.